Skip to content
Industrial Error Code Fixes
Go back

Amana ASX Air Conditioner Error Codes

⚡ Quick Answer

Amana ASX guide for LED flash codes, pressure-switch faults, compressor overload, control-board faults, thermistors, and low-voltage checks.

⚡ AT A GLANCEScroll down for full repair guide
What it meansAmana ASX guide for LED flash codes, pressure-switch faults, compressor overload, control-board faults, thermistors, and low-voltage checks.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededRun capacitor
Repair intent

Need this fixed instead of diagnosed?

Amana ASX guide for LED flash codes, pressure-switch faults, compressor overload, control-board faults, thermistors, and low-voltage checks.

Likely parts to price

Price the common parts before you book service.

Run capacitor

Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.

Flame sensor

Price this first on furnace ignition faults after cleaning and safety checks.

Igniter

Common furnace start failure part. Confirm connector and model compatibility.

Control board

Higher-cost part to price only after power, sensor, and wiring checks.

Amana ASX Air Conditioner Error Codes — What They Mean

The Amana ASX series (ASX13, ASX14, ASX16) are residential central air conditioners manufactured by Daikin (which owns both Amana and Goodman brands). The ASX uses the same outdoor control board, compressor platform, and flash-code diagnostic system as equivalent Goodman GSX units. If you have an ASX, the flash codes below apply directly — Amana and Goodman share service parts and diagnostic logic across the entire lineup.

Jump to Fix

Amana ASX LED Flash Code Reference

Flash SequenceFault
1 flashNormal — standby
2 flashesHigh-pressure switch open
3 flashesLow-pressure switch open
4 flashesCompressor protection device open (thermal overload)
5 flashesControl board fault
6 flashesOutdoor ambient thermistor fault
7 flashesDischarge temperature thermistor fault
Rapid flashLow voltage — check 24VAC transformer

Common Causes by Code

Step-by-Step Fix

  1. Locate the LED — Open the electrical access panel on the Amana ASX outdoor unit. The control board is mounted near the contactor. The LED flashes the fault code repeatedly until the fault is cleared or power is cycled.
  2. For 2 flashes (high pressure) — Confirm the condenser fan is running. Use an amp clamp on the fan motor wire — compare to nameplate. Test the capacitor with a capacitor meter. If the fan is running normally, clean the coil.
  3. For 3 flashes (low pressure) — Connect manifold gauges. A system with no refrigerant should not be operated — running a compressor without refrigerant (and the oil it carries) damages it quickly. Find and fix the leak before recharging.
  4. For 4 flashes (compressor protection) — Wait 30 minutes after shutdown before testing. Measure both legs of supply voltage at the disconnect under load. Unbalanced voltage (more than 2% imbalance) causes overheating in scroll compressors.
  5. Clear and test — After repairs, power up and monitor for the first cooling cycle. Confirm suction and discharge pressures are within the expected range for the ambient conditions.

Parts Often Needed

PartNotes
Dual run capacitorMost common ASX failure; shared compressor and fan capacitor
Contactor2-pole; check contact gap and coil pull-in voltage
High-pressure switchSpade terminals; direct swap
Low-pressure switch50 PSIG cutout for R-410A
Ambient thermistorFor Code 6; usually on a pigtail connector
Control boardFor Code 5; verify fuse and transformer first

Need Replacement Parts?

Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

Refrigerant service on the Amana ASX requires EPA 608 certification and proper manifold gauge equipment. Amana (Daikin/Goodman) offers a Lifetime Compressor Warranty on some ASX models for the original registered homeowner — check warranty status before authorizing a compressor replacement, as the part may be covered at no cost.


Need a professional? Compare HVAC repair options before replacing parts.
Compare Repair Options
Share this post on:

Previous Post
Carrier AC E3 Error Code: IPM Module Fault Diagnosis and Fix
Next Post