Alto-Shaam PT100 RTD temperature sensor
Use for E-01/E-02 sensor faults after checking the probe connector and resistance.
Alto-Shaam oven codes identify RTD probe, heat, fan, water-fill, steam, and control faults on Vector and Combitherm ovens.
Alto-Shaam oven codes identify RTD probe, heat, fan, water-fill, steam, and control faults on Vector and Combitherm ovens.
Parts to price first
Use for E-01/E-02 sensor faults after checking the probe connector and resistance.
Match voltage, wattage, and oven model before ordering.
Price after confirming the fan is not obstructed and the motor has failed.
Use for E-30 water supply faults after checking pressure and inlet screens.
Alto-Shaam manufactures commercial ovens including the Vector multi-cook oven and Combitherm combi oven, used in high-volume foodservice and hotel banquet operations.
| Code | Meaning | Urgency |
|---|---|---|
| E-01 | Cabinet temperature sensor fault | Medium |
| E-02 | Heating element fault | High |
| E-03 | Oven overtemperature | Critical |
| E-04 | Door interlock fault | Medium |
| E-10 | Control board fault | High |
| F-01 | Fan motor fault | High |
| Code | Meaning |
|---|---|
| E-01 | Cavity sensor fault |
| E-02 | Steam temperature sensor fault |
| E-10 | Heating element fault |
| E-20 | Fan fault |
| E-30 | Water supply fault |
| E-40 | Drain fault |
E-01/E-02 (sensor faults): Test the cavity temperature sensor resistance. Alto-Shaam uses RTD (PT100) sensors on Combitherm models. Replace if out of spec.
E-10 (heating element): Measure element resistance between heating element terminals. Open circuit = failed element. Match replacement element to oven model voltage and wattage.
E-20/F-01 (fan fault): Check fan motor for obstruction in the oven cavity. Test motor capacitor (single-phase motors). Verify correct rotation direction after any motor replacement.
E-30 (water supply): Check water supply valve position and supply pressure. Inspect inlet valve screen for scale. Alto-Shaam Combitherm requires filtered water — check water filter saturation.
E-03 (overtemp): Critical — do not operate. Investigate thermostat, element control, or gas valve issue before resuming use.
| Part | Notes |
|---|---|
| RTD temperature sensor | Alto-Shaam OEM — PT100 type |
| Heating element | Match to model voltage/wattage |
| Cavity fan motor | Replace if blocked or bearing failed |
| Water inlet valve | For E-30 |
Before ordering, match the refrigeration part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Alto-Shaam authorized service handles control board replacement, gas system work, and calibration after major repairs.