Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
It’s 95°F outside and your AC has been running for three hours straight. Your thermostat reads 80°F — four degrees above setpoint — and the vents are blowing air that feels barely cool. This is “AC not cooling enough,” and it’s the most common HVAC complaint of summer. The causes range from a $12 filter to a $1,500 refrigerant repair. Here’s how to tell which one you’re dealing with.
Your air conditioner is running — the compressor is on, the fans are spinning — but the house won’t reach the temperature you’ve set. The supply air at your vents might feel mildly cool or even lukewarm instead of the cold air you expect (typically 55–60°F at the vent).
This symptom has five primary causes:
There’s also a non-failure cause that generates a lot of service calls: the unit is simply undersized for the conditions. On extreme heat days (95°F+), many residential AC systems are designed to maintain an indoor temperature 20°F below outdoor — meaning 75°F indoors when it’s 95°F outside. If you’re expecting 68°F indoors during a heat wave, you may be expecting more than the system can deliver.
A clogged air filter is the single most preventable cause of poor cooling. When airflow is restricted, two things happen: (1) the evaporator coil can’t absorb heat from return air efficiently, and (2) the coil surface temperature drops below freezing and ice forms, blocking airflow even further. Eventually you get an ice block instead of a coil.
Check: Pull your filter and hold it to a light. If it’s gray and opaque, replace it immediately.
Common filter sizes: 16x25x1, 20x25x1, 16x20x1, 20x20x1. The size is printed on the filter frame.
After replacing: If the coil was iced over, turn the system to FAN ONLY mode for 30 minutes to let the ice melt before resuming cooling mode. Running a frozen AC system can damage the compressor.
Go to your air handler (the indoor unit — usually in a closet, attic, or utility room). Look at the refrigerant lines going into the unit. The larger insulated line (suction line) should feel cold — like a cold beer can. It should not be encased in ice.
If you see ice on the suction line or on the coil itself:
If the coil freezes again within a few hours, the problem is low refrigerant — not a filter issue.
The outdoor condenser unit is a giant heat radiator. Its job is to dump the heat it absorbed from inside your home into the outdoor air. If the condenser coil fins are clogged with cottonwood seeds, grass clippings, or dirt, it can’t reject heat efficiently. The refrigerant pressure rises, the system works harder, and cooling capacity drops.
How to clean:
Also check the clearance around the unit. There should be at least 18 inches of clear space on all sides. Overgrown shrubs or fencing too close to the unit recirculate hot exhaust air, killing efficiency.
While the outdoor unit is running (or trying to run), watch the fan blade on top of the condenser. It should be spinning at full speed. If it’s:
A failed capacitor is the most common culprit and one of the cheaper fixes ($20–40 in parts, $150–250 with labor).
The TXV meters refrigerant flow into the evaporator coil. A failed TXV can cause symptoms identical to low refrigerant: the system runs but doesn’t cool, with lower-than-normal suction line temperature and abnormal pressures. TXV diagnosis requires refrigerant gauges — you’ll need a technician. However, if a technician has already confirmed refrigerant charge is correct and the system still won’t cool, a TXV diagnosis is the right next step.
If you’ve completed the steps above and the system still isn’t cooling adequately, it’s time for a professional refrigerant check. Signs that point to low refrigerant:
Adding refrigerant without finding the leak is a temporary fix. A good tech will find the leak with a UV dye test or electronic leak detector, repair it, then recharge to the manufacturer’s specification (in PSI or superheat/subcooling targets — not just “pounds of refrigerant”).
| Part | Why You Need It | Approx. Cost |
|---|---|---|
| AC Air Filter MERV 8 20x25x1 | Clogged filter kills airflow and freezes coils | $8–$18 |
| Dual Run Capacitor 45/5 µF 440V | Failed capacitor prevents compressor or condenser fan from starting | $18–$35 |
| AC Condenser Fan Motor 1/5 HP | Failed motor means no heat rejection at the outdoor unit | $55–$120 |
| AC Fin Comb Coil Straightener | Bent condenser fins block airflow through coil | $12–$22 |
| AC Coil Cleaner Foam Spray | Removes grime from condenser and evaporator coils | $12–$20 |
| Contactor 2-Pole 30A | Burned contactor prevents compressor from receiving power | $15–$28 |
Need replacement parts? Search for parts and tools on Amazon.
Call an HVAC technician when:
Average repair costs:
Q: My AC is running constantly but the house is only 2–3 degrees warmer than the setpoint. Is this a problem?
A: On a very hot day (above 95°F), this can be normal — your system is working at maximum capacity to hold close to setpoint. If it’s happening on moderate days (75–80°F outside) and the system is running without reaching setpoint, something is wrong. Check the filter first, then schedule a refrigerant check.
Q: Can I add refrigerant myself?
A: Legally, no — unless you hold an EPA 608 certification. Refrigerants (R-410A, R-22, R-32) are regulated substances. DIY recharge kits sold at hardware stores use different refrigerants and can damage your system if mismatched. More importantly, adding refrigerant without fixing the leak is a waste of money. Find the leak first.
Q: The air coming from the vents is cool but not cold. What’s the target temperature?
A: Supply air from a properly operating AC system should be 15–20°F cooler than the return air temperature at the air handler. So if your return air is 75°F, supply air should be 55–60°F. You can measure this with a cheap thermometer at the supply vent. If you’re getting 68–72°F supply air, the system is underperforming — check refrigerant charge, filter, and coil cleanliness.
Q: My AC worked fine last summer. Why isn’t it cooling now?
A: Refrigerant leaks are the most common cause of a working-last-year, failing-this-year scenario. Slow leaks can take an entire cooling season to noticeably reduce charge. Also check: capacitors degrade over time (they don’t usually fail all at once), condenser coils may have gotten dirtier over winter, and filters should be replaced at season start.
Q: Should I close vents in unused rooms to improve cooling in other rooms?
A: No — this is a common misconception that actually reduces efficiency. Central AC systems are designed to move a specific volume of air. Closing vents raises static pressure in the duct system, reduces total airflow, and can cause the evaporator coil to freeze. Keep all vents open and use a zoning system or mini-splits if you want room-by-room temperature control.